Dec 11, 2014

Posted in Data Archive, 논문 / Papers

앵글과 철근을 조립한 PSRC 합성기둥의 휨 실험 / Flexural Test for Prefabricated Composite Columns Using Steel Angle and Reinforcing Bar [한국강구조학회 / Korean Society of Steel Construction] (2012.10)

31.앵글과 철근을 조립한 PSRC 합성기둥의 휨 실험

<DOWNLOAD>

– 저자 : 엄태성, 황현종, 박홍근, 이창남, 김형섭

PSRC column is a concrete encased steel angle column. In the PSRC column, the steel angles placed at the corner of the cross-section resists bending moment and compression load. The lateral re-bars welded to steel angles resist the column shear and the bond between the steel angle and concrete. In the present study, current design procedures in KBC 2009 were applied to the flexure-compression, shear, and bond design of the PSRC composite column. To verify the validity of the design method and failure mode, simply supported 2/3 scaled PSRC and correlated SRC beams were tested under two point loading. The test parameters were the steel angle ratio and lateral bar spacing. The test results showed that the bending, shear, and bond strengths predicted by KBC 2009 correlated well with the test results. The flexural strength of the PSRC specimens was much greater than that of the SRC specimen with the same steel ratio because the steel angles were placed at the corner of the column section. However, when the bond resistance between the steel angle and concrete was not sufficient, brittle failures such as bond failure of the angle, spalling of cover concrete, and the tensile fracture of lateral re-bar occurred before the development of the yield strength of PSRC composite section. Further, if the weldability and toughness of the steel angle were insufficient, the specimen was failed
by the fracture of the steel angle at the weld joint between the angle and lateral bars.